Review



ti2 inverted spinning disc confocal sdc microscope  (Nikon)


Bioz Verified Symbol Nikon is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Nikon ti2 inverted spinning disc confocal sdc microscope
    Ti2 Inverted Spinning Disc Confocal Sdc Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 11744 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ti2+inverted+spinning+disc+confocal+sdc+microscope/ECLIPSE+Ti2/pm40056119-175-8-7
    Average 99 stars, based on 11744 article reviews
    ti2 inverted spinning disc confocal sdc microscope - by Bioz Stars, 2026-09
    99/100 stars

    Images

    Related Articles

    Fluorescence:

    Article Title: Extreme pH Tolerance in Peptide Coacervates Mediated by Multivalent Hydrogen Bonds for Enzyme-Triggered Oral Drug Delivery.
    Article Snippet: Biopolymer-based complex coacervates hold promising prospects in the field of biomedicine.. However, their low stability in environments with extreme pH and high salt concentrations, largely due to weakly charged biomacromolecules and insufficient understanding of their assembly processes, has hindered their practical applications in oral drug delivery.. Here, we have developed Dopa-containing peptide-based complex coacervates that are stable across a wide range of pH (1−11) and salt concentrations.

    Microscopy:

    Article Title: Extreme pH Tolerance in Peptide Coacervates Mediated by Multivalent Hydrogen Bonds for Enzyme-Triggered Oral Drug Delivery.
    Article Snippet: Biopolymer-based complex coacervates hold promising prospects in the field of biomedicine.. However, their low stability in environments with extreme pH and high salt concentrations, largely due to weakly charged biomacromolecules and insufficient understanding of their assembly processes, has hindered their practical applications in oral drug delivery.. Here, we have developed Dopa-containing peptide-based complex coacervates that are stable across a wide range of pH (1−11) and salt concentrations.

    Article Title: MolPhase, an advanced prediction algorithm for protein phase separation
    Article Snippet: For in vitro droplet assay, samples were placed on clean cover slides and imaged using a Leica DMi8 (Leica Microsystems) equipped with an HCX PL APO 100×/1.4 oil objective, ORCA-Flash4.0 LT3 sCMOS camera (Hamamatsu), and a solid-state Spectra-X light engine (Lumencor). .. In vivo cell images were acquired on a Nikon Ti2 inverted spinning disc confocal (SDC) microscope (Nikon) equipped with a confocal spinning head (Yokogawa CSU-W1), a 100×1.45NA Plan-Apo objective, and a back-illuminated sCMOS camera (Orca-Fusion; Hamamatsu). .. Excitation light was provided by 488-nm/150 mW (Vortran) (for Alexa 488), 561-nm/100 mW (Coherent) (for mRuby2) laser combiner (iLAS system; GATACA Systems).

    Article Title: MolPhase: An Advanced Phase Separation Predictor and an Investigation of Phytobacterial Effector in Plant
    Article Snippet: For in vitro droplet assay, samples were placed on clean cover slides and imaged using a Leica DMi8 (Leica Microsystems) equipped with an HCX PL APO 100x/1.4 oil objective, ORCA-Flash4.0 LT3 sCMOS camera (Hamamatsu), and a solid-state Spectra-X light engine (Lumencor). .. In vivo cell images were acquired on Nikon Ti2 inverted spinning disc confocal (SDC) microscope (Nikon) equipped with a confocal spinning head (Yokogawa CSU-W1), a 100x 1.45NA Plan-Apo objective and a back-illuminated sCMOS camera (Orca-Fusion; Hamamatsu). .. Excitation light was provided by 488-nm/150mW (Vortran) (for Alexa 488), 561-nm/100mW (Coherent) (for mRuby2) laser combiner (iLAS system; GATACA Systems).

    In Vivo:

    Article Title: MolPhase, an advanced prediction algorithm for protein phase separation
    Article Snippet: For in vitro droplet assay, samples were placed on clean cover slides and imaged using a Leica DMi8 (Leica Microsystems) equipped with an HCX PL APO 100×/1.4 oil objective, ORCA-Flash4.0 LT3 sCMOS camera (Hamamatsu), and a solid-state Spectra-X light engine (Lumencor). .. In vivo cell images were acquired on a Nikon Ti2 inverted spinning disc confocal (SDC) microscope (Nikon) equipped with a confocal spinning head (Yokogawa CSU-W1), a 100×1.45NA Plan-Apo objective, and a back-illuminated sCMOS camera (Orca-Fusion; Hamamatsu). .. Excitation light was provided by 488-nm/150 mW (Vortran) (for Alexa 488), 561-nm/100 mW (Coherent) (for mRuby2) laser combiner (iLAS system; GATACA Systems).

    Article Title: MolPhase: An Advanced Phase Separation Predictor and an Investigation of Phytobacterial Effector in Plant
    Article Snippet: For in vitro droplet assay, samples were placed on clean cover slides and imaged using a Leica DMi8 (Leica Microsystems) equipped with an HCX PL APO 100x/1.4 oil objective, ORCA-Flash4.0 LT3 sCMOS camera (Hamamatsu), and a solid-state Spectra-X light engine (Lumencor). .. In vivo cell images were acquired on Nikon Ti2 inverted spinning disc confocal (SDC) microscope (Nikon) equipped with a confocal spinning head (Yokogawa CSU-W1), a 100x 1.45NA Plan-Apo objective and a back-illuminated sCMOS camera (Orca-Fusion; Hamamatsu). .. Excitation light was provided by 488-nm/150mW (Vortran) (for Alexa 488), 561-nm/100mW (Coherent) (for mRuby2) laser combiner (iLAS system; GATACA Systems).



    Similar Products

    99
    Nikon ti2 inverted spinning disc confocal sdc microscope
    Ti2 Inverted Spinning Disc Confocal Sdc Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ti2+inverted+spinning+disc+confocal+sdc+microscope/ECLIPSE+Ti2/pm40056119-175-8-7
    Average 99 stars, based on 1 article reviews
    ti2 inverted spinning disc confocal sdc microscope - by Bioz Stars, 2026-09
    99/100 stars
      Buy from Supplier

    90
    Nikon ti2 inverted spinning disc confocal (sdc) microscope
    Ti2 Inverted Spinning Disc Confocal (Sdc) Microscope, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/ti2+inverted+spinning+disc+confocal+sdc+microscope/pm38565952-315-9-16
    Average 90 stars, based on 1 article reviews
    ti2 inverted spinning disc confocal (sdc) microscope - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results